Line 1: | Line 1: | ||
====== DSA Acoustic Analysis ====== | ====== DSA Acoustic Analysis ====== | ||
+ | Follow the guided steps below on how to set-up an Acoustic or Octave Analysis in EDM to use with Spider hardware.\\ | ||
===== Create Test ===== | ===== Create Test ===== | ||
+ | In EDM, select to create a new test. From the New Test Wizard, select the **Acoustic Analysis** test type.\\ | ||
+ | {{: | ||
+ | Next, give the test a name and description.\\ | ||
+ | {{: | ||
+ | Finally, select the signal types that are wanted. The options include Auto Power Spectra (APS), Tachometer (TACHO), Octave Analysis (OCT), and Sound Level Meter (SLM). You are **unable** to add more signal types to be computed once the test is created. Press **Finish** to create the test.\\ | ||
+ | {{: | ||
===== Test Configuration ===== | ===== Test Configuration ===== | ||
- | ===== Input Channels ===== | + | For Acoustic Analysis, there are two unique parameters that may need to be set up, //Octave Filter// and //Sound Level Meter//. Please go here for more information on basic [[dsa: |
- | ===== Run Test ===== | + | |
+ | === Octave Filter Parameters | ||
+ | If Octave Filters are being applied, their parameters must first be set.\\ | ||
+ | |||
+ | //Octave Resolution// | ||
+ | |||
+ | //Low/High Frequency Band//- Defines the low and high frequency of the measurement in Hz.\\ | ||
+ | |||
+ | //Average Mode//- Defines the averaging type: exponential, | ||
+ | |||
+ | //Frequency Weighting// | ||
+ | |||
+ | //Time Trace Frequency// | ||
+ | |||
+ | //Trace Update Times//- Defines the time trace display duration. Select a larger update time to create longer time trace display duration.\\ | ||
+ | {{: | ||
+ | |||
+ | === Sound Level Meter (SLM) Parameters | ||
+ | If the SLM is being used, the parameters must first be set.\\ | ||
+ | |||
+ | //Time Trace Type//- Defines the time weighting including L, Leq and LE.\\ | ||
+ | |||
+ | //Analysis Period//- Specifies the time duration for each analysis period.\\ | ||
+ | |||
+ | //Result Update Time(s)//- Defines how many times the result will be updated.\\ | ||
+ | |||
+ | //Result History//- Defines the measurement length of the result history.\\ | ||
+ | {{: |