Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
dsa:fft [2024/05/29 15:20] – [Input Channels] dsain_go-ci.comdsa:fft [2024/07/17 19:39] (current) – [Input Channels] dsain_go-ci.com
Line 2: Line 2:
 Follow the guided steps below on how to set-up a FFT Analysis in EDM to use with Spider hardware.\\ Follow the guided steps below on how to set-up a FFT Analysis in EDM to use with Spider hardware.\\
 ===== Create Test ===== ===== Create Test =====
 +
 +<slider :dsa:pasted:20240521-142436.png>
 +<slider :dsa:pasted:20240521-142445.png>
 +<slider :dsa:pasted:20240521-142702.png>
 +</slider>
 +
 In EDM, select to create a new test. From the New Test Wizard, select the **FFT Analysis** test type.\\ In EDM, select to create a new test. From the New Test Wizard, select the **FFT Analysis** test type.\\
-{{:dsa:pasted:20240521-142436.png}}+
 Next, give the test a name and description.\\ Next, give the test a name and description.\\
-{{:dsa:pasted:20240521-142445.png}}+
 Finally, select the signal types that are wanted. You can select more than one signal type. Additionally, there Time History Stats can be selected to be calculated as well. You are **unable** to add more signal types to be computed once the test is created. Press **Finish** to create the test.\\ Finally, select the signal types that are wanted. You can select more than one signal type. Additionally, there Time History Stats can be selected to be calculated as well. You are **unable** to add more signal types to be computed once the test is created. Press **Finish** to create the test.\\
-{{:dsa:pasted:20240521-142702.png}}+
 ===== Test Configuration ===== ===== Test Configuration =====
 Before testing, the **Analysis Parameters** must be configured to ensure all the data is properly measured.\\ Before testing, the **Analysis Parameters** must be configured to ensure all the data is properly measured.\\
Line 33: Line 39:
 The input channels will now need to be set up. All sensors will to be properly configured before testing. The Input Channels menu can be found through **Setup → Input Channels**.\\  {{ :dsa:pasted:20240521-152103.png }}\\   The input channels will now need to be set up. All sensors will to be properly configured before testing. The Input Channels menu can be found through **Setup → Input Channels**.\\  {{ :dsa:pasted:20240521-152103.png }}\\  
  
-**Measurement Quantity**\\  Defines the physical unit that will be measured by the sensor connected to the channel.\\**Sensitivity**\\  Sets the proportionality factor for the measurement (millivolts per engineering unit) given as a parameter of the sensor.\\+**Measurement Quantity**\\  Defines the physical unit that will be measured by the sensor connected to the channel.\\ 
 +**Sensitivity**\\  Sets the proportionality factor for the measurement (millivolts per engineering unit) given as a parameter of the sensor.\\
  
 **Input Mode**\\  There are six modes in which the inputs can operate:\\ **Input Mode**\\  There are six modes in which the inputs can operate:\\