| Line 35: | Line 35: | ||
| **Mode shape**- Imports the FEA mode shapes from a Universal File ('' | **Mode shape**- Imports the FEA mode shapes from a Universal File ('' | ||
| + | |||
| + | FIXME **Screenshot: | ||
| + | {{: | ||
| + | |||
| + | The **MAC table** has one row for each EMA mode and one column for each FEA mode. Each cell is the MAC between that pair of modes. | ||
| + | |||
| + | **How to read the table:** | ||
| + | * Each EMA mode should have one FEA mode with a high MAC (typically above 80–90%) and low values for all the others. That FEA mode is its match. | ||
| + | * If the modes are listed in the same order, the high values form a diagonal line. | ||
| + | * An EMA mode with no high value has no matching FEA mode. The FEA model may be missing that mode, or the test may not have measured it well. | ||
| + | * Two EMA modes that both match the same FEA mode may be one mode that was picked twice, or the test points may be too few to tell the shapes apart. | ||
| + | |||
| + | **NOTE:** The EMA and FEA shapes must have the same measurement points. If they do not, EDM shows //" | ||
| + | |||
| + | ===== Frequency Error ===== | ||
| + | |||
| + | The **Relative error of modal frequency** row pairs each EMA mode with the FEA mode closest in frequency and shows the difference as a percentage of the EMA frequency: | ||
| + | |||
| + | //Error = |f(EMA) − f(FEA)| / f(EMA) × 100%// | ||
| + | |||
| + | **NOTE:** This pairing is by frequency only. Always check the MAC table to make sure the paired modes also have the same shape. Two modes can have close frequencies but different shapes. | ||
| + | |||
| + | ===== Display MAC Chart ===== | ||
| + | |||
| + | Click **Display MAC chart** to show the MAC table as a 3D bar chart. Each bar is one EMA-FEA pair, and its height is the MAC value. | ||
| + | |||
| + | FIXME **Screenshot: | ||
| + | {{: | ||
| + | |||
| + | **Default**- Resets the view of the chart. | ||
| + | |||
| + | **Export chart**- Saves the chart as a '' | ||
| + | |||
| + | Calculate the MAC before you open the chart. | ||
| + | |||
| + | ===== Animating the Shapes ===== | ||
| + | |||
| + | Right-click the Shape pane to animate the shapes in the **Animation** pane: | ||
| + | |||
| + | **Match EMA Points / Match FEA Points**- Links the DOFs in the table to the points of the geometry in the Animation pane. | ||
| + | |||
| + | **EMA Animate Display / FEA Animate Display**- Animates the enabled mode of the EMA or FEA shape. | ||
| + | |||
| + | Animate an EMA mode and its matching FEA mode one after the other to compare them visually. | ||
| + | |||
| + | FIXME **Screenshot: | ||
| + | {{: | ||
| + | |||
| + | **NOTE:** Each DOF must have a valid format (for example '' | ||
| + | |||
| + | ===== FAQs ===== | ||
| + | |||
| + | **Why does Calculate MAC show " | ||
| + | |||
| + | **Why are all the MAC values low?**- The mapping may be wrong (for example, the FEA model is rotated relative to the test geometry), or the DOF directions in the test do not match the model axes. Check the mapping and the DOF directions. | ||
| + | |||
| + | **Why did my FEA shapes disappear? | ||
| + | |||
| + | **Does disabling a mode remove it from the MAC?**- No. The **Enabled** check box only controls which mode is shown and animated. All the modes are always included. | ||