Differences
This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
| pa-general [2026/01/29 18:16] – reid_go-ci.com | pa-general [2026/01/30 15:38] (current) – [UI & Tools] reid_go-ci.com | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | ====== | + | ====== |
| **User guide can be found through the Help tool on the ribbon:** | **User guide can be found through the Help tool on the ribbon:** | ||
| Line 10: | Line 9: | ||
| {{: | {{: | ||
| - | =====New Project===== | + | ===== New Project ===== |
| - | + | ||
| + | ==== Analysis Type ==== | ||
| Projects store analysis settings and are associated with specified data files. There is no limit to project creation but only one can be active at any time per instance of PA. **Project wizard and test selection screens may differ from those shown below based on bundle and testing options purchased on license.** | Projects store analysis settings and are associated with specified data files. There is no limit to project creation but only one can be active at any time per instance of PA. **Project wizard and test selection screens may differ from those shown below based on bundle and testing options purchased on license.** | ||
| - | {{: | + | {{: |
| + | |||
| + | Project creation begins with the selection of an analysis type. There is a strong possibility that you know and understand your testing parameters and requirements, | ||
| + | |||
| + | [[https:// | ||
| + | |||
| + | If you are unable to find the test type which meets your requirements, | ||
| + | |||
| + | Click Next > after desired test type is found. | ||
| + | |||
| + | ==== Data Source ==== | ||
| + | |||
| + | Set project name and description and then select a template if you would like to create your project from a previous save state. Then select your data files from the source file browser. To upload .atfx .csv .txt or .tdms files from your PC, click on Add single source file. To browse files in your EDM select __Data File Browser__. Click Next > to continue to analysis options. | ||
| + | |||
| + | {{: | ||
| + | |||
| + | ==== Signal Computation Selection ==== | ||
| + | |||
| + | Figure displays options for an FFT analysis, options will vary depending on test type. APS and FRF are the most used analysis types. | ||
| + | |||
| + | {{: | ||
| + | |||
| + | Click Finish to complete project wizard setup. | ||
| + | |||
| + | ===== UI & Tools ===== | ||
| + | |||
| + | Once the project is loaded, the signal display window will appear by default. | ||
| + | |||
| + | {{: | ||
| + | |||
| + | Current and previous tests will be displayed in the Recent Projects window on the upper left of the screen. | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | From this window, the time streams and computations which are needed for your testing requirements can be placed in signal display window. | ||
| + | |||
| + | Before running test, select Setup drop down from ribbon and left click Project Configuration. | ||
| + | |||
| + | {{: | ||
| - | Project creation begins with the selection of an analysis type. There is a strong possibility that you know and understand your testing parameters and requirements, | + | {{:picture8.png?400}} |
| - | {{:picture4.png?400|}} | + | Make selections for block size / spectral lines to determine ∆f and dynamic range. Overlap ratio, recommended at least 50% for Hanning window. Average mode and average number should be adjusted based on testing requirements, |
| - | Set project name and description and then select a template if you would like to create your project from a previous save state. Then select your data files from the source file browser. To upload .atfx .csv .txt or .tdms files from your PC, click on Add single source file. To browse files in your EDM select __Data File Browser__. Click Next > to continue to analysis options. | + | {{:picture9.png?400}} |
| - | {{: | + | [[pa-data-conditioning]] |
| - | Figure displays | + | For further processing |
| - | {{:picture6.png?400|}} | + | {{:: |
| - | When first loaded into project only the time stream data, data source files selected for analysis, will be present. Before running | + | Right of the Display window is the Control Panel. The main testing drive operations are found in this section. As well as test configurations |
| - | {{:picture7.png?400|}} | + | Once setup is complete select Run from the control panel in the upper right of the screen. |
| - | {{:picture8.png?400|}} | + | {{:picture10.png?400}} |
| - | Make selections for block size / spectral lines to determine ∆f and dynamic range. Overlap ratio, recommended at least 50% for Hanning window. Average mode and average number based on testing requirements. Window selection can be left as Hanning for most testing applications; | + | During testing the options of: Hold, Next, Frame, Stop & Save will become available. If held (paused) the continue option will be present. |
| - | {{:picture9.png?400|}} | + | {{:: |
| - | [[pa-data-conditioning|]] | ||
| - | For further processing options select Setup drop down and left click Data Conditioning. Data conditioning capabilities are supported for FFT Spectral Analysis, Time-stamp, Order-Tracking, | + | Processed data will display in windows |
| - | {{: | ||
| - | {{: | + | {{: |
| - | Once setup is complete select Run from the control panel in the upper right of the screen. | ||