Differences
This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
| vcs:ui-overview:config [2026/02/12 21:56] – created reid_go-ci.com | vcs:ui-overview:config [2026/02/18 21:01] (current) – [Save/Recording Setup] reid_go-ci.com | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| =====VCS UI Config===== | =====VCS UI Config===== | ||
| + | |||
| + | Configuration tools are generally similar across testing types. | ||
| + | |||
| + | ====Shaker Parameters==== | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | Edit Parameters allows you to adjust the shaker limits in acceleration, | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | Limits can typically be found through OEM site or product specification sheet. | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | If the shaker in use is not set as default but has already been used in testing, shaker parameters can be imported through the Load from library option located on the bottom ribbon of the page. | ||
| + | List of Shaker parameters from OEM can be imported to fill out library. | ||
| + | |||
| + | **Test Parameters** | ||
| + | Testing parameters shown in figure display a random signal test. The test parameters will vary by test type. All test types conducting an FFT analysis will include options for blocking and windowing. | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | Lines selection box will allow you to choose the spectral lines within a given block. | ||
| + | **DOF**, degrees of freedom, is the number of independent FFT contributing to a statistical result in a PSD diagram. | ||
| + | |||
| + | **Average** is the number of blocks of data that are used to compute a PSD. Averaging can include different forms of weighting and often has overlapping and windowing which contribute to the data not being independent from each other. | ||
| + | |||
| + | **Overlap ratio** describes how much data from the nth block will be contained in the n+1 block. | ||
| + | |||
| + | **Delta frequency (Hz)** also known as frequency resolution is the spacing between spectral lines and is often referred to as FFT bins. It is the amount of definition able to be seen in an APS spectrum. | ||
| + | |||
| + | **Control Strategy;** There are four options for this parameter. | ||
| + | |||
| + | **Sigma clipping** gives control over data variance. | ||
| + | |||
| + | **Drive limit (volt Pk)** sets an abort criterion at the specified output level. | ||
| + | |||
| + | **Frequency range** defines range of FFT analysis measurement. | ||
| + | |||
| + | **Advanced Settings** include options for test limiting and notching, ramp up rates, spectrum resolution and performance optimization. | ||
| + | |||
| + | **Abort sensitivity** can be customized or scaled so that the test will either allow for testing to continue while being pushed into abort range territory for higher or lower ranges. | ||
| + | |||
| + | ====Pre-Test Parameters==== | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | Before testing begins it is important to run a check to build a new FRF, or use previous FRF, based on a low input drive. | ||
| + | |||
| + | ====Test Profile==== | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | Test profiles for random tests will only display a broadband signal covering the defined frequency range. | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | Output magnitude can be adjusted by dB or acceleration units. | ||
| + | |||
| + | **RMS limits** | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | This page displays calculated values based on the test profile and abort limits previously set. Values can be scaled by profile RMS, same as Scale RMS, or by manually adjusting values of alarm and abort. | ||
| + | |||
| + | |||
| + | ====Run Schedule==== | ||
| + | |||
| + | Run schedule allows the user to define the testing process and resulting actions after a test is completed. | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | To create run schedule you simply click on the desired entry or event on the item to insert window. | ||
| + | |||
| + | ====Limit channels==== | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | Limit channels allow for test controls to be placed at frequencies to adjust the abort test and alarm profiles. | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | ===Event Actions=== | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | Event actions panel allows the user to define testing run schedule events. | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | ====Digital IO==== | ||
| + | |||
| + | Digital Input/ | ||
| + | |||
| + | ====File Directory==== | ||
| + | |||
| + | Allows you to control where data is stored and naming conventions of files. | ||
| + | |||
| + | ====Save/ | ||
| + | |||
| + | User can define when data should be saved to system. | ||
| + | |||
| + | Save options vary by test type to allow for greater customization of data saving. | ||
| + | |||
| + | ====Output Settings==== | ||
| + | |||
| + | Output settings give user control over which output channel should control shakers. | ||
| + | |||
| + | =====Control Panel===== | ||
| + | |||
| + | Control Panel allows users to conduct testing and acts as a shortcut to other vital testing parameter windows. | ||
| + | |||
| + | **Connect/ | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | Will attempt to connect to selected hardware device. | ||
| + | |||
| + | **Run** | ||
| + | Begins Run process. | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | Pre-test check process will begin once you left-click OK. Pre-test confirmation page displays testing information and gives directory location final choice. | ||
| + | |||
| + | {{:: | ||
| + | |||
| + | If the check is successful there will be no warnings displayed and you may conclude Pre-test confirmation with Proceed. | ||
| + | |||
| + | **Pause** | ||
| + | Pause option will become active once the test run schedule begins. | ||
| + | |||
| + | **Stop** | ||
| + | This command will end the testing process. | ||
| + | |||
| + | **Save** | ||
| + | This will save the frequency domain data from the last time block created. | ||
| + | |||
| + | **Config** | ||
| + | |||
| + | [[config|]] | ||
| + | |||
| + | Configuration window can be selected on the ribbon as well as through the control panel Magenta Config button. | ||
| + | |||
| + | Configuration tools are generally similar across testing types, but there will be unique parameters for each testing type. | ||