 =====VCS UI Hardware Menu===== =====VCS UI Hardware Menu=====
  
-===Tools===+Hardware configuration within VCS begins with Spider connection.
  
-Spider Configuration: Displays detected modules as well as currently selected spider’s information regarding model type serial number and EDM version.+Then continues with the test type selection to matches physical model. 
 + 
 +Hardware setup continues with Shaker parameters within [[config|]] 
 + 
 +Inputs and signal control follow from the Top Toolbar to match sensor setup. 
 +====Ribbon -> Tools==== 
 + 
 +**Spider Configuration:** Displays detected modules as well as currently selected spider’s information regarding model type serial number and EDM version.  Spider configuration is available when you are not connected to a spider currently. 
 + 
 +Options include renaming spider system, setting as default system, importing a new system and IP address configuration.
  
 {{::spider_setup.png?600|}} {{::spider_setup.png?600|}}
    
-Spider Date & Time Settings: Set Date & Time to be synchronized with PC or to custom setup.  +**DIO** Digital input & output allows for customization of input and output channels 
 + 
 +A spider must be selected from the modules page to access DIO 
 + 
 +{{:vcs:ui-overview:dio.png?600|}} 
 + 
 +**Spider Date & Time Settings:** Set Date & Time to be synchronized with PC or to custom setup.  
  
 Global Settings: Allows customization of interface appearance, units, formatting, notifications and plot properties.   Global Settings: Allows customization of interface appearance, units, formatting, notifications and plot properties.  
 +
 +Working Folder: Sets the file browser/PC location of recording and saves data, as well as generated reports.  
  
 {{::global_settings.png?200|}} {{::global_settings.png?200|}}
 +
 +===Calibration -> Sensor Calibration===
 +
 +{{:vcs:ui-overview:hardware_sensor_calibration.png?400|}}
 +
 +Allows for channel selection for sensor calibration.  Previous/old sensitivity will be populated; new calibrated sensitivity will populate directly to input values after sensor calibration is complete.
 +
 +===Hardware Self Test===
 +
 +{{hardware-menu:pasted:20260219-164710.png?600|}}
 +
 +Self-test will generate a drive output, so it is important to take precaution before running examination.
 +
 +
 +
 +
    
-Working Folder: Sets the file browser/PC location of recording and saves data, as well as generated reports.   
  
-===Report=== 
  
-Generates report of selected results or parametersa word document with the relevant information will open and save.  +====Top Toolbar -> Inputs====  
 +  
 +{{::inputs_tab.png?600|}} 
 + 
 +Input Channels for Test window allows you to define active channels as well as control and monitor channels.  You can set the NameMeasurement, EU, Sensitivity and Input mode for the type of sensor used in test.  High-pass and max range voltage range can also be set.   
 + 
 +===Settings== 
 + 
 +Shortcut to Global settings as described in Tools -> Global settings.   
 + 
 +Global settings include engineering units, which is important for sensor/input configuration, VCS settings, used for setup specific and test type information as well as common settings, and controls pass-filters for all incoming data.