Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
vcs:ui-overview:signals-tab [2026/02/13 21:49] reid_go-ci.comvcs:ui-overview:signals-tab [2026/02/18 21:11] (current) – [Live Signal Tab] reid_go-ci.com
Line 1: Line 1:
 ===== VCS UI Signals Tab ===== ===== VCS UI Signals Tab =====
  
-==== Signals ====+==== Top Toolbar -> Signals ====
  
 Signals gives user control over settings related to display, appearance, data recording/saving and processing options. Signals gives user control over settings related to display, appearance, data recording/saving and processing options.
Line 21: Line 21:
 PC FRF signals give user options to create transfer functions for desired input (response) and output (excitation) channels.  Also allows for customization of FRF and coherence calculations. PC FRF signals give user options to create transfer functions for desired input (response) and output (excitation) channels.  Also allows for customization of FRF and coherence calculations.
  
 +====Recent Test Tab====
  
 +{{:vcs:ui-overview:recent_tests_signals.png?600|}}
 +
 +**New Test**
 +Opens New Test Wizard will send user back to selection screen including testing type and shaker arrangement.  
 +
 +**Open Test** 
 +Brings up display with previous tests conducted. 
 +
 +{{::open_test.png?600|}}
 + 
 +Tests can then be directly exported or opened from this menu.  Double click to open or select test before clicking export.  Test statistics can be selected from the right-most column corresponding to each test.  
 +
 +{{::run_statistics.png?500|}}
 +
 +Test group functionality gives user the ability to carry over testing configuration between tests.  Inputs, profiles and additional settings are carried through group tests.  No reconfiguration is required.
 +
 +**Test Group**
 +
 +{{:vcs:ui-overview:test_group_editor.png?600|}}
 +
 +====Live Signal Tab====
 +Live Signals will update in real time as testing is conducted.  The time stream data will update continuously.  The Block and frequency derived data will be updated as each new block is processed.  For testing conducted with short block intervals this will be very similar to time stream data, but under long block collection testing parameters, the data can take several seconds to update.
 +
 +{{:vcs:ui-overview:signals_display.png?600|}}
 +
 +Run Folders show previous runs within testing setup.  It will also include saved data and time history within the run folder.  
 +Data Files tab allows files and folders to be uploaded to the test.  This can include timestream data from previous runs in common formats such as .txt, .csv, , .atfx and other common formats.  
 +
 +===Time Signal AVD Settings=== 
 +
 +**Top Toolbar -> Settings** controls signal pass filters.  Gives several commonly used options for signal filtering which can be applied to all incoming data.
 +
 +{{:vcs:ui-overview:avd_filters.png?600|}}