 {{:vds:new_entry_setup.png?600|}} {{:vds:new_entry_setup.png?600|}}
  
 +===Orientation===
  
 +{{:vds:orientation.png?400|}}
  
 +Entry creation starts with an orientation selection.  Orientation options are available for single and triaxial sensors
 +
 +Enable alarm & Enable Tacho options are found on the orientation screen as well.  Enabling these options will make a new tab appear on the screen to input settings for selected feature.
 +
 +To make this orientation default enable the "Make default for this point" option in the bottom left of the screen
 +
 +===Parameter===
 +
 +{{:vds:parameter.png?400|}}
 +
 +Parameter settings can be saved and selected from parameter library for quick entry creation.
 +
 +Parameter settings include spectrum type measurement quantity filtering averaging and block settings.  **For auto-diagnostic features to function the measurement quantity must be set to Velocity** This is not the sensor output measurement.
 +
 +===Alarm===
 +
 +{{:vds:alarm.png?400|}}
 +
 +Alarm settings can be saved and loaded from library database.  Alarm settings include the signal level units and measurement as well as the various intensities of the alarm.
 +
 +===Sensor===
 +
 +{{:vds:sensor.png?400|}}
 +
 +Sensors can be saved and loaded from the database library.  This information will come from sensor manufacturer and includes sensitivity and input mode.
 +
 +===Data===
 +
 +{{:vds:data.png?400|}}
 +
 +Give the entry a name and description